From 936ef744358b3facc471cd618938a1943173b7bb Mon Sep 17 00:00:00 2001 From: "E. Joshua Rigler" <erigler@usgs.gov> Date: Sat, 16 Apr 2022 10:59:33 -0600 Subject: [PATCH] Add GUT to geomagio/Metadata.py A new FGE+ObsRIO test system is being deployed to Guam. For now, we simply create an entry in Metadata.py so that variation filtering can be be applied to these new data. The calibration parameters are defaults for non-high-latitude FGE fluxgages. --- geomagio/Metadata.py | 32 ++++++++++++++++++++++++++++++++ 1 file changed, 32 insertions(+) diff --git a/geomagio/Metadata.py b/geomagio/Metadata.py index 74c2b347..ded542a9 100644 --- a/geomagio/Metadata.py +++ b/geomagio/Metadata.py @@ -344,6 +344,38 @@ _INSTRUMENT_METADATA = [ }, }, }, + { + "network": "NT", + "station": "GUT", + "start_time": None, + "end_time": None, + "instrument": { + "type": "FGE", + "channels": { + # each channel maps to a list of components to calculate nT + # TODO: calculate these lists based on "FGE" type + "U": [{"channel": "U_Volt", "offset": 0, "scale": 320.0}], + "V": [{"channel": "V_Volt", "offset": 0, "scale": 320.0}], + "W": [{"channel": "W_Volt", "offset": 0, "scale": 320.0}], + }, + ## this info should get updated when available + # "electronics": { + # "serial": "E0542", + # # these scale values are used to convert voltage + # "x-scale": 313.2, # V/nT + # "y-scale": 312.3, # V/nT + # "z-scale": 312.0, # V/nT + # "temperature-scale": 0.01, # V/K + # }, + # "sensor": { + # "serial": "S0419", + # # these constants combine with instrument setting for offset + # "x-constant": 36958, # nT/mA + # "y-constant": 36849, # nT/mA + # "z-constant": 36811, # nT/mA + # }, + }, + }, { "network": "NT", "station": "HON", -- GitLab