"""Simulate metadata service until it is implemented.
"""
def get_instrument(observatory, start_time=None, end_time=None, metadata=None):
"""Get instrument metadata
Args:
observatory: observatory code
start_time: start time to match, or None to match any.
end_time: end time to match, or None to match any.
metadata: use custom list, defaults to _INSTRUMENT_METADATA
Returns:
list of matching metadata
"""
metadata = metadata or _INSTRUMENT_METADATA
return [
m
for m in metadata
if m["station"] == observatory
and (end_time is None or m["start_time"] is None or m["start_time"] < end_time)
and (start_time is None or m["end_time"] is None or m["end_time"] > start_time)
]
"""
To make this list easier to maintain:
- List NT network stations first, then other networks in alphabetical order
- Within networks, alphabetize by station, then start_time.
"""
_INSTRUMENT_METADATA = [
{
"network": "NT",
"station": "BDT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 313.2}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 312.3}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 312.0}],
},
"electronics": {
"serial": "E0542",
# these scale values are used to convert voltage
"x-scale": 313.2, # V/nT
"y-scale": 312.3, # V/nT
"z-scale": 312.0, # V/nT
"temperature-scale": 0.01, # V/K
},
"sensor": {
"serial": "S0419",
# these constants combine with instrument setting for offset
"x-constant": 36958, # nT/mA
"y-constant": 36849, # nT/mA
"z-constant": 36811, # nT/mA
},
},
},
{
"network": "NT",
"station": "NEW",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
{
"network": "NT",
"station": "LLO",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
{
"network": "NT",
"station": "SJT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 320.0}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 320.0}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 320.0}],
},
## this info should get updated when available
# "electronics": {
# "serial": "E0542",
# # these scale values are used to convert voltage
# "x-scale": 313.2, # V/nT
# "y-scale": 312.3, # V/nT
# "z-scale": 312.0, # V/nT
# "temperature-scale": 0.01, # V/K
# },
# "sensor": {
# "serial": "S0419",
# # these constants combine with instrument setting for offset
# "x-constant": 36958, # nT/mA
# "y-constant": 36849, # nT/mA
# "z-constant": 36811, # nT/mA
# },
},
},