Skip to content
Snippets Groups Projects

Add GUA to geomagio/Metadata.py

Merged Erin (Josh) Rigler requested to merge ghsc/users/erigler/geomag-algorithms:master into master
1 file
+ 87
0
Compare changes
  • Side-by-side
  • Inline
+ 87
0
@@ -321,6 +321,61 @@ _INSTRUMENT_METADATA = [
},
},
},
{
"network": "NT",
"station": "GUA",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
{
"network": "NT",
"station": "GUT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 320.0}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 320.0}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 320.0}],
},
## this info should get updated when available
# "electronics": {
# "serial": "E0542",
# # these scale values are used to convert voltage
# "x-scale": 313.2, # V/nT
# "y-scale": 312.3, # V/nT
# "z-scale": 312.0, # V/nT
# "temperature-scale": 0.01, # V/K
# },
# "sensor": {
# "serial": "S0419",
# # these constants combine with instrument setting for offset
# "x-constant": 36958, # nT/mA
# "y-constant": 36849, # nT/mA
# "z-constant": 36811, # nT/mA
# },
},
},
{
"network": "NT",
"station": "HON",
@@ -344,6 +399,38 @@ _INSTRUMENT_METADATA = [
},
},
},
{
"network": "NT",
"station": "HOT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 320.0}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 320.0}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 320.0}],
},
## this info should get updated when available
# "electronics": {
# "serial": "E0542",
# # these scale values are used to convert voltage
# "x-scale": 313.2, # V/nT
# "y-scale": 312.3, # V/nT
# "z-scale": 312.0, # V/nT
# "temperature-scale": 0.01, # V/K
# },
# "sensor": {
# "serial": "S0419",
# # these constants combine with instrument setting for offset
# "x-constant": 36958, # nT/mA
# "y-constant": 36849, # nT/mA
# "z-constant": 36811, # nT/mA
# },
},
},
{
"network": "NT",
"station": "NEW",
Loading