Skip to content

Updated Kaguya CCD Center

Sorry, I noticed that while double checking stuff in #231 Here's the relevant bit from the IK

Detector CCD Parameters
---------------------------------------------------------------------------

   The following table summarizes TC individual camera detector 
   parameters. As these data show the detectors are all line arrays.


      -----------------------------------------------------------------
             parameter                     TC1             TC2
      -----------------------------------------------------------------
      Pixel Size, microns
          Cross-track                      7.0              7.0
          Along-track                      7.0              7.0
      Detector Array Size
          Cross-track                      4096             4096
          Along-track                      1                1
      Detector Array Center (*1)
          Cross-track                      2048.5           2048.5
          Along-track                      1.0              1.0
      -----------------------------------------------------------------

    (*1) Center of the first pixel is defined as "1.0".


   These values are incorporated in the keywords below; pixel sizes 
   are converted to MILLIMETERS.
                    ^^^^^^^^^^^

      \begindata

      INS-131351_PIXEL_SAMPLES  = ( 4096        )
      INS-131351_PIXEL_LINES    = ( 1           )
      INS-131351_CENTER         = ( 2048.5, 1.0 )       
      INS-131351_PIXEL_SIZE     = ( 0.007    )

      INS-131371_PIXEL_SAMPLES  = ( 4096        )
      INS-131371_PIXEL_LINES    = ( 1           )
      INS-131371_CENTER         = ( 2048.5, 1.0 )       
      INS-131371_PIXEL_SIZE     = ( 0.007    )

      \begintext

Merge request reports

Loading