Updated Kaguya CCD Center
Sorry, I noticed that while double checking stuff in #231 Here's the relevant bit from the IK
Detector CCD Parameters
---------------------------------------------------------------------------
The following table summarizes TC individual camera detector
parameters. As these data show the detectors are all line arrays.
-----------------------------------------------------------------
parameter TC1 TC2
-----------------------------------------------------------------
Pixel Size, microns
Cross-track 7.0 7.0
Along-track 7.0 7.0
Detector Array Size
Cross-track 4096 4096
Along-track 1 1
Detector Array Center (*1)
Cross-track 2048.5 2048.5
Along-track 1.0 1.0
-----------------------------------------------------------------
(*1) Center of the first pixel is defined as "1.0".
These values are incorporated in the keywords below; pixel sizes
are converted to MILLIMETERS.
^^^^^^^^^^^
\begindata
INS-131351_PIXEL_SAMPLES = ( 4096 )
INS-131351_PIXEL_LINES = ( 1 )
INS-131351_CENTER = ( 2048.5, 1.0 )
INS-131351_PIXEL_SIZE = ( 0.007 )
INS-131371_PIXEL_SAMPLES = ( 4096 )
INS-131371_PIXEL_LINES = ( 1 )
INS-131371_CENTER = ( 2048.5, 1.0 )
INS-131371_PIXEL_SIZE = ( 0.007 )
\begintext