"""Simulate metadata service until it is implemented.
"""
def get_instrument(observatory, start_time=None, end_time=None, metadata=None):
"""Get instrument metadata
Args:
observatory: observatory code
start_time: start time to match, or None to match any.
end_time: end time to match, or None to match any.
metadata: use custom list, defaults to _INSTRUMENT_METADATA
Returns:
list of matching metadata
"""
metadata = metadata or _INSTRUMENT_METADATA
return [
m
for m in metadata
if m["station"] == observatory
and (end_time is None or m["start_time"] is None or m["start_time"] < end_time)
and (start_time is None or m["end_time"] is None or m["end_time"] > start_time)
]
"""
To make this list easier to maintain:
- List NT network stations first, then other networks in alphabetical order
- Within networks, alphabetize by station, then start_time.
"""
_INSTRUMENT_METADATA = [
{
"network": "NT",
"station": "BDT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 313.2}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 312.3}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 312.0}],
},
"electronics": {
"serial": "E0542",
# these scale values are used to convert voltage
"x-scale": 313.2, # V/nT
"y-scale": 312.3, # V/nT
"z-scale": 312.0, # V/nT
"temperature-scale": 0.01, # V/K
},
"sensor": {
"serial": "S0419",
# these constants combine with instrument setting for offset
"x-constant": 36958, # nT/mA
"y-constant": 36849, # nT/mA
"z-constant": 36811, # nT/mA
},
},
},
{
"network": "NT",
"station": "BRT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 506},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 505.6},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 506},
],
},
},
},
{
"network": "NT",
"station": "FDT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
{
"network": "NT",
"station": "NEW",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
{
"network": "NT",
"station": "LLO",
"start_time": None,
"end_time": None,
"instrument": {
"type": "Narod",
"channels": {
"U": [
{"channel": "U_Volt", "offset": 0, "scale": 100},
{"channel": "U_Bin", "offset": 0, "scale": 500},
],
"V": [
{"channel": "V_Volt", "offset": 0, "scale": 100},
{"channel": "V_Bin", "offset": 0, "scale": 500},
],
"W": [
{"channel": "W_Volt", "offset": 0, "scale": 100},
{"channel": "W_Bin", "offset": 0, "scale": 500},
],
},
},
},
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
{
"network": "NT",
"station": "SJT",
"start_time": None,
"end_time": None,
"instrument": {
"type": "FGE",
"channels": {
# each channel maps to a list of components to calculate nT
# TODO: calculate these lists based on "FGE" type
"U": [{"channel": "U_Volt", "offset": 0, "scale": 320.0}],
"V": [{"channel": "V_Volt", "offset": 0, "scale": 320.0}],
"W": [{"channel": "W_Volt", "offset": 0, "scale": 320.0}],
},
## this info should get updated when available
# "electronics": {
# "serial": "E0542",
# # these scale values are used to convert voltage
# "x-scale": 313.2, # V/nT
# "y-scale": 312.3, # V/nT
# "z-scale": 312.0, # V/nT
# "temperature-scale": 0.01, # V/K
# },
# "sensor": {
# "serial": "S0419",
# # these constants combine with instrument setting for offset
# "x-constant": 36958, # nT/mA
# "y-constant": 36849, # nT/mA
# "z-constant": 36811, # nT/mA
# },
},
},